Skip to product information
1 of 9

ResMed

AirSense 10 Elite CPAP with ClimateLineAir

AirSense 10 Elite CPAP with ClimateLineAir

SKU:37206

Regular price $819.00 USD
Regular price Sale price $819.00 USD
Sale Sold out
Shipping calculated at checkout.
View full details

AirSense 10 Elite with ClimateLine Air

Copy of RX Required if Applicable to U.S. Residents

The new "S 10 series," officially named the ResMed AirSense 10 Elite, has arrived. The AirSense 10 AutoSet Elite model is the fixed pressure CPAP machine that will deliver one set therapy pressure through the night as prescribed by your physician.

Many new users of CPAP therapy may be confused about which machine is right for them. On the one hand, you have auto adjusting CPAP machines, and on the other, you have fixed pressure "standard CPAP" machines. What is the difference?

The ResMed CPAP Elite, a fixed pressure model, provides one setting of therapy throughout your night's sleep and does not fluctuate from that setting unless a ramp feature is enabled. This feature increases therapy from the minimal amount to the prescribed amount over a period of time to allow you to fall asleep at a lower setting.

Fixed pressure devices are the most commonly prescribed devices, and your physician establishes this number (i.e., 8cm/h2o) based off your sleep study. In cases where a home sleep test was used and an auto CPAP trialed, he/she may set it based on a compliance report of the median average of therapy needed.

We program your settings as listed on your CPAP prescription and can make changes to your settings as they adjust over time via an SD card that can be mailed to our office. Many veteran users of therapy elect to use a fixed setting they have used and are comfortable with (some even elect to forego ramp feature).

The AirSense 10 AutoSet Elite continues the superior quality of this therapy device where the S9 Elite left off. Still available in the new model is EPR (expiratory pressure relief) as well as a new modification to the ramp setting with AutoRamp. SmartStart allows the user to put his/her mask on and begin breathing, allowing the machine to turn on and start therapy.

Special Features & Benefits for the AirSense 10 Elite

  • HumidAir- An integrated heated humidifier is built-in to the CPAP ResMed device. You can use the ClimateLineAir heated hose or a standard SlimLine lightweight hose tube.
  • AutoRamp -This technology starts your therapy pressure at a low setting and increases therapy pressure once sleep onset is detected. This is a great feature for new CPAP users so they fall asleep faster and with little to no interruptions. The AirSense 10 AutoSet will let patients sleep throughout the night as the device will drop the pressure to allow the user to get back to sleep faster without the feeling of an overwhelming high-pressure setting and without the need to manually hit the ramp button again.
  • ClimateLineAir - The integrated heated humidifier is now a standard feature, with the option to purchase standard SlimLine hose tubing or ClimateLine heated hose tubing. The heated line tubing is great for people sensitive to dryness from the use of CPAP, as it promotes humidity throughout the entire hose.
  • Advanced Event Detection -This feature can tell the difference between obstructive sleep apnea events or central apnea events (central sleep apnea is treated with Bi-level therapy or ASV therapy and is most often not treated with standard CPAP pressure). Additionally, it also delivers expiratory pressure relief so that the user feels more comfortable when exhaling.
  • SmartStart -This allows you to simply put the mask on and start breathing, which will initiate the device to turn on automatically and begin therapy. Please note this setting is not activated when we ship your AirSense 10 CPAP machine unless you specify otherwise.
  • Wireless Data Transmission: Transmits compliance data via a wireless signal (Only available for use in the United States).

Included in This Package

  • (1) AirSense 10 Elite with HumidAir Humidifier
  • (1) New humidifier water chamber tub
  • (1) SlimLine tubing (unless you select the optional ClimateLine Air)
  • (1) Power Supply
  • (1) Travel Carry Bag
  • (1) SD Card (already inserted)

Optional Accessories for Purchase

Is the ResMed AirSense 10 AutoSet Machine a BiPAP?

Yes, it is. BiPAP, or BPAP, stands for bi-level positive airway pressure. It helps push air into the lungs to maintain a consistent breathing pattern throughout the night while sleeping. BiPAP machines are often used by sleep apnea patients with low oxygen levels or high pressure settings.

Unlike a CPAP machine, a BiPAP device has two pressure settings, and using one or the other will depend on the advice of your sleep physician.

Recommended Replacement Schedule

  • Hose: Every 1-3 Months (or as needed)
  • Filter(s): Every 1-3 Months (or as needed if noticeable build up)
  • Water Chamber: Every 6-12 Months (or as needed)
  • Mask: As Needed
  • AC Power: 100-240V, 50-60Hz
  • Actual Weight: 44 oz. (2.75lbs)
  • Altitude Compensation: Auto
  • Associated Part Numbers: 37207, 37208, 37209, 37209
  • Battery Power: Optional DC/DC Converter Sold Separate
  • Compliance Meter: On screen display
  • Condition: New
  • Country of Origin: Australia
  • Data Storage Content: SD Card or Wireless Transmission (US Only) to Provider
  • DC Power: 24V ---3.75A
  • Dimensions: 4.57" x 10.04" x 5.91"
  • FAA Approved: Yes. Documentation may be required per airline
  • Filters: Standard or Hypo-Allergenic Disposable
  • Humidifier: Integrated with Optional Heated Tubing
  • Insurance Codes: E0601 HCPC
  • International Shipping: Yes International Shipping is available
  • Latex Free: Yes
  • Material Content: Flame Retardant Thermoplastic
  • Mode of Operation: Fixed Pressure
  • Pressure Range: 4cm-20cm/h2O
  • Ramp Time: Auto adjusting ramp feature
  • RX Required?: Yes, When Applicable for U.S. Residents
  • Shipping Weight: 6lbs
  • Sound Level: 26.6 dBA with uncertainty of 2 dBA
  • Special User Features: AutoRamp, Integrated Humidifier
  • Starting Ramp Pressure: Auto Ramp starting at 4cm/h2O
  • Travel Sized: Yes
  • US Shipping Cost: Free
  • Warranty: 2 Year

Q: How do I Adjust the AirSense/AirCurve 10 Comfort Settings?

A: To access and personalize your settings on the AirSense/AirCurve 10 machine, rotate the dial to highlight "My Options." Once the desired option is highlighted, press the dial to view and adjust your current settings.

Q: How Do I Adjust the Humidifier Settings?

A: In My Options, turn the dial to highlight Humidity Level and then press the dial.

Turn the dial to adjust the humidity level and press the dial to save the change. If you’re getting a dry nose or mouth, turn up the humidity. If you’re getting any moisture in your mask, turn down the humidity.

The humidifier enhances the air's moisture content, ensuring a more comfortable therapeutic experience. Equipped with the Climate Control enhanced Auto setting, this device automatically adjusts temperature and humidity to optimal levels for maximum comfort. Simply plug it in, press Start and enjoy a relaxing treatment.

You can also manually set the Humidity Level to Off or between 1 and 8, where 1 is the lowest humidity setting and 8 is the highest humidity setting. (Note: if you’re using a ClimateLineAir™ heated tube, you will need to turn the Climate Control setting on your device from “Auto” to “Manual” to access the humidity level setting.)

Q: How Do I Adjust Ramp Time?

A: In My Options, turn the dial to highlight Ramp Time and then press the dial.

Turn the dial to adjust the ramp time to your preferred setting and press the dial to save the change. Ramp Time is designed to make the beginning of therapy more comfortable and is the period during which the airflow pressure increases from a low start pressure to your prescribed treatment pressure. You can set your Ramp Time to Off, from 5 to 45 minutes.

Q: How Often Should I Replace AirSense/AirCurve 10 Machine Parts?

A: Regularly maintain your CPAP supplies, as dirt and wear can affect them. Check the water tub, air tubing, and filter frequently for damage.

Water Tank: Replace if it is leaking or has become cracked, cloudy or pitted. Replace if the seal is cracked or torn. Remove any white powder deposits using a solution of one part household vinegar to 10 parts water.

Hose Tubing: Replace if there are any holes, tears or cracks.

Machine Filter: Check the air filter and replace it at least every six months. Replace it more often if there are any holes or blockages by dirt or dust.